Gechy's power supply can be used within this frequency range. But if the frequency is too low, the efficiency will also be lower.
For example, when a S-200-24 is operated under 230VAC and rated load, if the frequency of AC input is 60 Hz, the efficiency is around 84%; However, if the frequency of AC input reduces to 50 Hz, the efficiency will be around 83.8%.
If the frequency is too high, the power factor of the S.P.S. with PFC (power factor correction) function will reduce and this also will cause higher leakage current. For example, when a SP-200-24 is operated under 230VAC and rated load, if the frequency of AC input is 60 Hz, the power factor is 0.93 and the leakage current is around 0.7mA;
However, if the frequency of AC input increase to 440 Hz, the power factor will decrease to 0.75 and the leakage current will rise to around 4.3mA.
Gechy electric co.,ltd specializing in the production of switching power supply. If doubt welcomes to call to consult. Thanks!